O, N determination in titanium samples
本文由 上??茖W(xué)儀器有限公司 整理匯編
2018-08-16 10:00 2145閱讀次數(shù)
文檔僅可預(yù)覽首頁(yè)內(nèi)容,請(qǐng)下載后查看全文信息!
立即下載
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nNickelbasket(90250)orAR2344nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:20mVnMinimumtime:15secnMaximumtime:3:00minnPostwaiting:30secnBaselinedeviation:200mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:6kWnTimePurge:20secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:75secPower(1):6kWPower(2):6kWSamplepreparationMakesurethatthesurfaceofthetitaniumisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterialandgiveitintoanickelbasket(90250orAR2344)(3)Placenickelbasketwithcalibrationmaterialorsampleinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.
登錄或新用戶注冊(cè)
請(qǐng)用手機(jī)微信掃描下方二維碼 快速登錄 或注冊(cè)新賬號(hào)
微信掃碼,手機(jī)電腦聯(lián)動(dòng)
更多資料
O, N determination in titanium samples
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nNickelbasket(90250)orAR2344nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:20mVnMinimumtime:15secnMaximumtime:3:00minnPostwaiting:30secnBaselinedeviation:200mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:6kWnTimePurge:20secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:75secPower(1):6kWPower(2):6kWSamplepreparationMakesurethatthesurfaceofthetitaniumisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterialandgiveitintoanickelbasket(90250orAR2344)(3)Placenickelbasketwithcalibrationmaterialorsampleinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊(cè)
O, N determination in titanium
O, N determination in titanium[詳細(xì)]
2024-09-28 04:37
產(chǎn)品樣冊(cè)
O, N determination in steel samples
O, N determination in steel samples[詳細(xì)]
2015-06-24 00:00
操作手冊(cè)
O, N determination in steel samples
O, N determination in steel samples[詳細(xì)]
2015-06-24 00:00
期刊論文
O, N determination in steel samples (single graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnGraphitecrucibles(90190)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Placeemptycrucible(90190)ontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊(cè)
O determination in copper samples
O determination in copper samples[詳細(xì)]
2015-06-24 00:00
操作手冊(cè)
O, N determination in steel samples (Inner and outer graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊(cè)
C, S determination in ore samples
C, S determination in ore samples[詳細(xì)]
2015-06-24 00:00
期刊論文
C, S determination in wood samples
SuitableAnalyzersnCS-580seriesnCS-2000(resistancefurnace)UsedAccessoriesn90160DisposableporcelainboatsnSuitablecalibrationmaterialfromNISTorotherSettingsnFurnaceTemperature:1350°CnComperatorlevel:20nminimumanalysistime:60secondsnmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200m.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof150mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊(cè)
C, S determination in coal samples
SuitableAnalyzersCS-580seriesCS-2000(resistancefurnace)UsedAccessories90160DisposableporcelainboatsSuitablecalibrationmaterialfromNISTorotherSettingsFurnaceTemperature:1350°CComperatorlevel:20minimumanalysistime:60secondsmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200μm.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof200mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware->Analyzetheunknownsamples.[詳細(xì)]
2018-08-16 10:00
產(chǎn)品樣冊(cè)
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[詳細(xì)]
2024-09-18 18:08
課件
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[詳細(xì)]
2024-09-28 00:08
專利
C, S determination in flue ash samples
C, S determination in flue ash samples[詳細(xì)]
2015-06-24 00:00
標(biāo)準(zhǔn)
C, S determination in pure iron samples
C, S determination in pure iron samples[詳細(xì)]
2024-09-18 22:38
專利
皮爾茲PNOZ s5 24VDC 2 n/o 2 n/o t
皮爾茲安全繼電器PNOZs524VDC2n/o2n/ot批準(zhǔn):CE,cULus認(rèn)證,TV,KOSHA,CCC應(yīng)用選項(xiàng):安全門監(jiān)控,瞬時(shí)緊急停止監(jiān)控,限位開關(guān),緊急停止延時(shí)監(jiān)控,光柵設(shè)備監(jiān)控器。4級(jí),光柵設(shè)備監(jiān)控器。2級(jí),非典型,光柵設(shè)備監(jiān)控器。2級(jí),典型值,安全斷電延時(shí)計(jì)時(shí)器操作模式:單通道,自動(dòng)復(fù)位,雙通道,手動(dòng)復(fù)位,觸點(diǎn)間短路檢測(cè),啟動(dòng)測(cè)試,手動(dòng)復(fù)位監(jiān)控,不檢測(cè)觸點(diǎn)間短路,自檢測(cè),編程延時(shí)斷電產(chǎn)品標(biāo)準(zhǔn):EN60947-5-1標(biāo)準(zhǔn):EN60204-1,EN62061,ENISO13849-1,VDE0113-1供電電壓(V):24,0源型:DC終端型:插件皮爾茲安全繼電器PNOZs524VDC2n/o2n/ot終端類型:螺絲端子瞬時(shí)安全觸點(diǎn)數(shù)量:2延時(shí)安全觸點(diǎn)數(shù)量:2半導(dǎo)體輸出數(shù)量:1可選次數(shù):0.04s,0.10s,0.20s,0.30s,0.40s,0.50s,0.60s,0.70s,0.80s,1.00s,1.50s,10.00s,100.00s,12.00s,120.00s,14.00s,140.00s,15.00s,150.00s,16.00s,160.00s,180.00s,2.00s,2.50s,20.00s,200.00s,210.00s,240.00s,25.00s,3.00s,3.50s,30.00s,300.00s,35.00s,4.00s,40.00s,5.00s,50.00s,6.00s,60.00s,7.00s,70.00s,8.00s,80.00s,90.00s停止類別:0/1在DC13處的Zda電流I(6個(gè)循環(huán)/Z小):4.0A在AC1處的Zda電流5:3.0A寬度尺寸:22.5mm高度尺寸:98.0mm深度尺寸:120.0mm總重:245g凈重:235g以攝氏度一表示的環(huán)境溫度:-10-55°C皮爾茲安全繼電器PNOZs524VDC2n/o2n/ot[詳細(xì)]
2018-10-02 10:01
產(chǎn)品樣冊(cè)
Thermo Scientific?46i-HL型N?O分析儀
46i-HL型高濃度分析儀使用極ng確的校準(zhǔn)曲線,保證了儀器在2,000 ppm的濃度范圍內(nèi)有準(zhǔn)確的線性輸出,并且可以在雙量程和自動(dòng)量程模式中使用。此外,46i-HL型高濃度分析儀還具有自動(dòng)壓力和溫度補(bǔ)償功能,增強(qiáng)了對(duì)沖擊和振動(dòng)的抵抗力,同時(shí)提高了產(chǎn)品的特性和靈敏性。[詳細(xì)]
2020-01-15 15:30
產(chǎn)品樣冊(cè)
Thermo Scientific? 46i型N?O分析儀
46i型分析儀使用極ng確的校準(zhǔn)曲線,保證了儀器在50ppm的濃度范圍內(nèi)有準(zhǔn)確的線性輸出,并且可以在雙量程和自動(dòng)范圍模式中使用。[詳細(xì)]
2024-09-29 10:04
產(chǎn)品樣冊(cè)
PILZ繼電器PNOZ s3 24VDC 2 n/o
PILZ繼電器PNOZs324VDC2n/o技術(shù)參數(shù)[詳細(xì)]
2018-11-23 10:00
產(chǎn)品樣冊(cè)
Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES
Traditionally, geological samples are analyzed using flame atomic absorption (FAAS) and/or radial ICP-OES with a vertical torch. Achieving high sample throughput at a low cost per analysis for geochemical samples can be challenging when using these techniques. [詳細(xì)]
2024-09-29 22:17
標(biāo)準(zhǔn)
皮爾茲PNOZ s4 C 24VDC 3 n/o 1 n/c
皮爾茲安全繼電器PNOZs4C24VDC3n/o1n/c產(chǎn)品版本:1.0批準(zhǔn):CE,cULus認(rèn)證,TV,KOSHA,CCC應(yīng)用選項(xiàng):安全門監(jiān)控,瞬時(shí)緊急停止監(jiān)控,限位開關(guān),光柵設(shè)備監(jiān)控器。4級(jí),光柵設(shè)備監(jiān)控器。2級(jí),非典型,光柵設(shè)備監(jiān)控器。2級(jí),典型值操作模式:單通道,自動(dòng)復(fù)位,雙通道,手動(dòng)復(fù)位,觸點(diǎn)間短路檢測(cè),啟動(dòng)測(cè)試,手動(dòng)復(fù)位監(jiān)控,不檢測(cè)觸點(diǎn)間短路,自檢測(cè)皮爾茲安全繼電器PNOZs4C24VDC3n/o1n/c產(chǎn)品標(biāo)準(zhǔn):EN60947-5-1標(biāo)準(zhǔn):EN60204-1,EN62061,ENISO13849-1,VDE0113-1供電電壓(V):24,0源型:DC終端型:插件終端類型:彈簧式端子瞬時(shí)安全觸點(diǎn)數(shù)量:3輔助觸點(diǎn)數(shù)量:1半導(dǎo)體輸出數(shù)量:1停止類別:0皮爾茲安全繼電器PNOZs4C24VDC3n/o1n/c在DC13處的Zda電流I(6個(gè)循環(huán)/Z小):5.0A在AC1處的Zda電流5:5.0A寬度尺寸:22.5mm高度尺寸:100.0mm深度尺寸:120.0mm總重:200g凈重:190g以攝氏度一表示的環(huán)境溫度:-10-55°C皮爾茲安全繼電器PNOZs4C24VDC3n/o1n/c[詳細(xì)]
2018-10-02 10:01
產(chǎn)品樣冊(cè)
Copyright 2004-2026 yiqi.com All Rights Reserved , 未經(jīng)書面授權(quán) , 頁(yè)面內(nèi)容不得以任何形式進(jìn)行復(fù)制
參與評(píng)論
登錄后參與評(píng)論