氧化鋯微量氧分析儀ZO-301:氧化鋯微量氧分析儀ZO-301是一款智能化微量氧分析儀,分6個(gè)自動(dòng)檔位,均可測試精度,靈敏度高,測氣快,多用于氣體分裝、空分企業(yè)、玻璃生產(chǎn),冶煉、石油、石化、半導(dǎo)體器件生產(chǎn),電子電路焊接,磁性材料生產(chǎn),大學(xué),醫(yī)院,實(shí)驗(yàn)室等方面。這是一款穩(wěn)定、可靠的儀器,使用單位遍布全國各省市和東南亞地區(qū)。氧化鋯氧分析儀ZO-301技術(shù)指標(biāo)1、測量范圍:0.1ppm1**%O2,量程自動(dòng)切換,LED數(shù)字顯示2、基本誤差:P<100ppm±5ppm,P>100pm±3%3、零點(diǎn)和量程漂移:P<100ppm±5ppm/24h,P>100ppm±3%/24h4、重復(fù)性誤差:P<100pm±2.5ppm,P>100ppm±1.5%5、時(shí)間常數(shù):<10s6、影響誤差:a、電壓波動(dòng):220v±10%,P<100ppm±2.5ppm,P>100ppm±1.5%b、頻率波動(dòng):50Hz±10%,P<100ppm±2.5ppm,P>100ppm±1.5%c、環(huán)境溫度:0-40度。,P<100ppm±7.5ppm,P>100ppm±4.5%d、流量波動(dòng):P<10ppm200ml/min±5ml/min<±5ppme、P<100ppm200ml/min±10ml/min<±2.5ppmP>100ppm200ml/miu±50ml/min<±3%7、信號輸出:0-10mA,4-20mA,分六檔,可預(yù)置,ZO-302型增加1-5V輸出。I,0.1-10ppm,II,0-1000ppm,III,0-1%V,0-10%VI,0-1**%8、溫度精控:750度±3度9、預(yù)熱時(shí)間:1h10、功耗:50W,Zda250W11、外形、開孔尺寸及重量ZO-301型:300×140×350mm(寬×高×深)7.3KgZO-302型:310×140×300mm(寬×高×深)7Kg開孔;312±1×142±1mm(寬×高)
登錄或新用戶注冊
請用手機(jī)微信掃描下方二維碼
快速登錄或注冊新賬號
微信掃碼,手機(jī)電腦聯(lián)動(dòng)
更多資料
-
氧化鋯微量氧分析儀 便攜式氧化鋯檢測儀的技術(shù)指標(biāo)
- 氧化鋯微量氧分析儀ZO-301:氧化鋯微量氧分析儀ZO-301是一款智能化微量氧分析儀,分6個(gè)自動(dòng)檔位,均可測試精度,靈敏度高,測氣快,多用于氣體分裝、空分企業(yè)、玻璃生產(chǎn),冶煉、石油、石化、半導(dǎo)體器件生產(chǎn),電子電路焊接,磁性材料生產(chǎn),大學(xué),醫(yī)院,實(shí)驗(yàn)室等方面。這是一款穩(wěn)定、可靠的儀器,使用單位遍布全國各省市和東南亞地區(qū)。氧化鋯氧分析儀ZO-301技術(shù)指標(biāo)1、測量范圍:0.1ppm1**%O2,量程自動(dòng)切換,LED數(shù)字顯示2、基本誤差:P<100ppm±5ppm,P>100pm±3%3、零點(diǎn)和量程漂移:P<100ppm±5ppm/24h,P>100ppm±3%/24h4、重復(fù)性誤差:P<100pm±2.5ppm,P>100ppm±1.5%5、時(shí)間常數(shù):<10s6、影響誤差:a、電壓波動(dòng):220v±10%,P<100ppm±2.5ppm,P>100ppm±1.5%b、頻率波動(dòng):50Hz±10%,P<100ppm±2.5ppm,P>100ppm±1.5%c、環(huán)境溫度:0-40度。,P<100ppm±7.5ppm,P>100ppm±4.5%d、流量波動(dòng):P<10ppm200ml/min±5ml/min<±5ppme、P<100ppm200ml/min±10ml/min<±2.5ppmP>100ppm200ml/miu±50ml/min<±3%7、信號輸出:0-10mA,4-20mA,分六檔,可預(yù)置,ZO-302型增加1-5V輸出。I,0.1-10ppm,II,0-1000ppm,III,0-1%V,0-10%VI,0-1**%8、溫度精控:750度±3度9、預(yù)熱時(shí)間:1h10、功耗:50W,Zda250W11、外形、開孔尺寸及重量ZO-301型:300×140×350mm(寬×高×深)7.3KgZO-302型:310×140×300mm(寬×高×深)7Kg開孔;312±1×142±1mm(寬×高)[詳細(xì)]
-
2018-10-05 10:00
產(chǎn)品樣冊
-
氧化鋯原理微量氧分析儀:WY78-200
- 氧化鋯原理微量氧分析儀:WY78-200氧化鋯氧量分析儀由以微處理機(jī)為核心的智能化信號轉(zhuǎn)換器和氧化鋯檢測器組成。用于在線測量被測氣中的氧濃度,輸出線性模擬量信號,使用方便、可靠、維護(hù)簡單。該儀器適用于如下領(lǐng)域:⑴空分制氮、化工流程氧含量自動(dòng)分析;⑵磁性材料等高溫?zé)Y(jié)爐的保護(hù)性氣體中氧含量分析;⑶電子行業(yè)保護(hù)性氣體中氧含量分析;⑷玻璃、建材行業(yè)氧含量分析。1氧化鋯氧量分析儀技術(shù)指標(biāo)1.1測量范圍:0.1ppm~1**%O2(3位LED數(shù)字顯示)1.2基本誤差:P<100ppm,±2%FSP≥100ppm,±2%FS1.3重復(fù)性:P<100ppm,±1.5%FSP≥100ppm,±1%FS1.4零點(diǎn)漂移和量程漂移:≯基本誤差1.5滯后時(shí)間:T90≤30秒1.6輸出信號:4~20mA(負(fù)載電阻≤750Ω),與輸出信號對應(yīng)的測量范圍為:0.1~100ppm、1~1000ppm、0.1~25%標(biāo)準(zhǔn)RS-232接口1.7溫控精度:700℃±2℃1.8升溫時(shí)間:~30min1.9測量值報(bào)警上、下限設(shè)定:上、下限設(shè)置值可在與輸出信號相對應(yīng)的測量范圍內(nèi)任意設(shè)定,報(bào)警接點(diǎn)容量為交流220伏,1安培1.10功耗:≤50W1.11電源220V±22VAC、50Hz±0.5[詳細(xì)]
-
2018-10-07 10:00
產(chǎn)品樣冊
-
氧化鋯氧分析儀/氧化鋯氧量分析儀(硫酸專用)型號:ZO-801S
- 氧化鋯氧分析儀/氧化鋯氧量分析儀(硫酸專用)型號:ZO-801S化鋯氧分析儀是近幾十年發(fā)展起來的新型測氧儀器,因其具有結(jié)構(gòu)簡單、維護(hù)方便、反應(yīng)速度快、測量范圍廣等特點(diǎn),而廣泛應(yīng)用于電力、冶金、供暖、建材、電子等部門,分析各種工業(yè)鍋爐及窯爐中煙氣的氧含量。ZO-801S氧化鋯氧分析儀由轉(zhuǎn)換器和檢測器組成,檢測器采用直插式探頭結(jié)構(gòu),不需取樣系統(tǒng),能及時(shí)反映鍋爐內(nèi)燃燒狀況,如與自控裝置配合使用,可有效地控制燃燒狀況,應(yīng)用于硫酸制造系統(tǒng)。氧化鋯氧分析儀/氧化鋯氧量分析儀(硫酸專用)主要特點(diǎn):大屏幕LCD顯示屏全中文操作菜單實(shí)時(shí)時(shí)鐘顯示可聯(lián)接打印機(jī),實(shí)現(xiàn)定時(shí)自動(dòng)打印具有定時(shí)自動(dòng)存儲功能、可隨時(shí)查看存儲數(shù)據(jù)具有無紙記錄儀功能,自動(dòng)記錄氧濃度隨時(shí)間的變化曲線具有RS232通訊口,可連接計(jì)算機(jī),實(shí)現(xiàn)實(shí)時(shí)數(shù)據(jù)傳輸,數(shù)據(jù)存儲、曲線趨勢圖、打印報(bào)表等功能可設(shè)置上、下限報(bào)警點(diǎn)、具有報(bào)警接點(diǎn)輸出可用標(biāo)準(zhǔn)氣在線校準(zhǔn)可選擇輸出電流為0-10mA或4-20mA技術(shù)指標(biāo):測量范圍:0~5、10、25%、50%O2(三位有效數(shù))精度:±2%線性度:量程的±1%(模擬量輸出)重復(fù)性:量程的±0.5%(模擬量輸出)穩(wěn)定性:量程的±2%/7d(零點(diǎn)程滿量程)負(fù)載電阻:0~1.6kΩ(0~10mA);0~800Ω(4~20mA)功耗:<80W電源:220V±10%環(huán)境溫度:轉(zhuǎn)換器:0~40℃;檢測器:-10~80℃樣氣溫度:0~700℃樣氣壓力范圍:-500~+500mmH2O響應(yīng)時(shí)間:≤5s(達(dá)90%測量值)檢測器長度:0.4m;0.8m;1.0m;1.2m[詳細(xì)]
-
2018-10-05 10:00
產(chǎn)品樣冊
-
上海湘潤介紹OXYMAT 64氧化鋯微量氧分析儀
- 上海湘潤實(shí)業(yè)有限公司為大家介紹西門子OXYMAT64微量氧氣分析儀上海湘潤實(shí)業(yè)有限公司為大家介紹SIEMENSOXYMAT64微量氧氣分析儀,西門子新出產(chǎn)品,我們就趕緊著為大家介紹推出了,如有更多需要,歡迎來電咨詢,優(yōu)勢高線性緊湊設(shè)計(jì)開放型接口(RS485,RS232,PROFIBUS)通過SIPROMGA實(shí)現(xiàn)分析儀的網(wǎng)絡(luò)維護(hù)和服務(wù)(可選)應(yīng)用工藝氣體的生產(chǎn):N2和CO2中的微量氧的測量焊接:高合金鋼,鈦等的焊接時(shí),惰性氣體中微量氧的測量空氣分離裝置:N2和惰性氣體中微量氧的的測量;CO2中微量氧的測量冶金,淬火:NH3中微量氧的測量食品制造:CO2中微量氧的測量(例:釀酒)化學(xué)應(yīng)用:聚乙烯工藝流體焊接系統(tǒng)設(shè)計(jì)高度為4HU,可安裝在:帶有鉸鏈的機(jī)架帶或不帶滑軌的機(jī)柜維修時(shí),前面面板可以卸下(連接便攜式電腦)樣氣連接-輸入:管徑為6mm或1/4的卡套連接-輸出:管徑為6mm或1/4的管連接高壓和低壓工藝條件可使用催化活躍型和非催化活躍型顯示屏和控制面板大屏幕LCD可同時(shí)顯示:-測量值(數(shù)字和棒圖顯示)-狀態(tài)欄-量程可通過菜單來調(diào)節(jié)液晶顯示器的對比度持久的LED背光顯示可擦洗的膜式鍵盤/前面板,帶有5個(gè)功能鍵5位阿拉伯?dāng)?shù)字測量值顯示(其中小數(shù)點(diǎn)占1位)通過菜單操作可進(jìn)行編程、組態(tài)、功能測試、標(biāo)定用戶幫助菜單以純文本格式顯示濃度測量值可通過棒圖圖形顯示;時(shí)間間隔可設(shè)定操作軟件采用2種語言:德文/英文,英文/法文,西班牙文/英文,意大利文/英文測量量程可從ppm量程切換到和%。輸入和輸出每個(gè)測量組分1個(gè)模擬輸出(由0,2,4~20mA,可編程)6個(gè)可任意配置的開關(guān)量輸入(例如:用于量程切換,處理來自樣氣處理系統(tǒng)的外部信號)6個(gè)可任意配置的繼電器輸出(例如:用于故障報(bào)警、維護(hù)請求、超限報(bào)警、外接電磁閥)2個(gè)可編程模擬量輸入(例如:用于校正交叉干擾或接入外部壓力傳感器信號)可另外擴(kuò)展8個(gè)開關(guān)量輸入和8個(gè)繼電器輸出(例如:可用來進(jìn)行多達(dá)四種標(biāo)氣的自動(dòng)標(biāo)定)通訊RS485為基本配置 選項(xiàng)RS485/RS232轉(zhuǎn)換器RS485/以太網(wǎng)轉(zhuǎn)換器RS485/USB轉(zhuǎn)換器通過PROFIBUSDP/PA接口接入網(wǎng)絡(luò)SIPROMGA軟件ContinuousGasAnalyzer,extractiveOXYMAT64Generalinformation2/130SiemensPA0120122■OverviewTheOXYMAT64gasanalyzerisusedforthetracemeasurementofoxygen.■BenefitsHighlinearityCompactdesignOpeninterfacearchitecture(RS485,RS232,PROFIBUS)SIPROMGAnetworkformaintenanceandserviceinformation(option)■ApplicationProductionoftechnicalgasesMeasurementsinN2andCO2WeldingMeasurementsinprotectivegasesduringweldingofhighlyal-loyedsteels,titanium,etc.SystemsforairseparationMeasurementsinN2andininertgases(e.g.Ne,Ar)MeasurementsinCO2FoodproductionMeasurementinCO2(e.g.breweries)ElectronicsindustryLow-pressureversionwithpumpFlowsolderingsystems■Design19"rackunitwith4HUforinstallation-inhingedframe-incabinetswithorwithouttelescoperailsFrontplateforservicepurposescanbepivoteddown(laptopconnection)Connectionsforsamplegas-Input:Clampingringconnectionforapipediameterof6mmor"-Output:Pipeconnectionwithdiameter6mmor"High-pressureandlow-pressureversionsCatalyticallyactiveandinactivecellDisplayandcontrolpanelLargeLCDfieldforsimultaneousdisplayof-Measuredvalue-Statusbar-MeasurementrangesContrastoftheLCDfieldadjustableviathemenuPermanentLEDbacklightingWashablemembranekeyboardwithfivesoftkeysFive-digitmeasured-valuedisplay(decimalpointcountsasonedigit)Menu-drivenoperationforparameterization,configuration,testfunctions,adjustmentOperatorsupportinplaintextGraphicaldisplayoftheconcentrationprogression;timeinter-valsparameterizableBi領(lǐng)ualoperatingsoftwareGerman/English,English/Spanish,French/English,Spanish/English,Italian/EnglishSwitchoverfromppmmeasuringrangeto%measuringrangeInputandoutputsOneanalogoutputpermedium(from0,2,4to20mA;NAMURparameterizable)Sixbinaryinputsfreelyconfigurable(e.g.formeasurementrangeswitchover,processingofexternalsignalsfromsamplepreparation)Sixrelayoutputsfreelyconfigurable(failure,maintenancerequest,maintenanceswitch,thresholdalarm,externalsole-noidvalves)Twoanaloginputsconfigurable(e.g.correctionofcross-interference,externalpressuresensor)Extensionwitheightadditionalbinaryinputsandeightaddi-tionalrelayoutputs,e.g.forautocalibrationwithuptofourcalibrationgasesCommunicationRS485presentinbasicunit(connectionfromtherear).OptionsRS485/RS232converterRS485/EthernetconverterRS485/USBconverterConnectiontonetworksviaPROFIBUSDP/PAinterfaceSIPROMGAsoftwareastheserviceandmaintenancetoolSiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT64Generalinformation2/131SiemensPA0120122OXYMAT64,membranekeyboardandgraphicdisplayDesignsPartstouchedbysamplegas,standardStatuslinetodisplaytheanalyzerstatus(programmable)LEDbacklitgraphicdisplayandmembranekeyboardwithnoticeableclickDisplayofconcentrationsasnumbersandbargraphDisplayofstart-of-scaleandfull-scalevaluesKeyboardtoentervaluesCLEARkeytodeleteinputsENTERkeytoacceptinputvaluesMEASkeytoreturntomeasurementmodeINFOkeyforhelpinplaintextESCkeytoabortinputsDisplayofcurrentmeasuringrangesEasyoperationmenucontrolusingthesoftkeysTwocodelevelsaccordingtoNAMUR(maintenanceandspecialistlevel)Gaspath19"rackunitSamplegaspathBushingPipeinletO2sensorBypasslineConnectionpiecesStainlesssteel,mat.no.1.4571StainlesssteelZrO2ceramicFPM(Viton)PTFE(Teflon)PressuresensorEnclosureDiaphragmSensoradapterBypassrestrictorPolycarbonateSiO4AluminumStainlesssteel,mat.no.1.4571FlowindicatorMeasurementpipeVariableareaSuspensionboundaryAnglepiecesDuranglassDuranglass,blackPTFE(Teflon)FKM(Viton)PressureswitchEnclosureMembranePolycarbonateNBRSiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT64Generalinformation2/132SiemensPA0120122Gaspath(high-pressureversion)GaspathOXYMAT64,high-pressureversionThesamplegaspressure(2000to6000hPa)isregulatedbythepressureregulator(3)atapprox.2000hPaorisprovidedbytheoperatorwith2000hPa.Thispressureisappliedattherestrictor(10).Therestrictor(10)reducesthepressuresuchthatasamplegasflowof15to30l/hiscreated.Thisflowissubdividedviathesamplegasrestrictor(11)andtheadjustablebypassrestrictor(6)suchthatthereisasamplegasflowof7.5l/hthroughthesensor.Ifthesamplegascanflowoffintotheatmosphereunhampered,thesamplegaspressurecorrespondstotheatmosphericpressure.Ifthesamplegasflowsoffviaanexhaustgasline,itworkslikeaflowresistance.Iftheresultingdynamicpressureexceeds100hPa(rel.),amaintenancerequestisoutput.Legendforthegaspathfigure1Samplegasinlet;inletpressure5Pressuresensor-withoutinternalpressureregulator:2000hPa(abs.),regulated6Bypassrestrictor-withinternalpressureregulator:2000...6000hPa(abs.)7Pressureswitch2Samplegasoutlet;samplegasflowsofffreeofdynamicpressure8Flowmeasuringtube3Pressureregulator(orderversion)9Purginggasconnection4O2sensor10RestrictorO2sensor(KAZ/KIZ)SiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT64Generalinformation2/134SiemensPA0120122■FunctionThemeasuringcellconsistsofacylindrical(pipe-shaped)ZrO2membrane.Thesamplegas(lowO2content)flowsataconstantratethroughtheinsideofthemembrane,whichisregulatedat650°C.Theexteriorofthesensorisexposedtotheambientair(approx.21%O2).BothsidesoftheZrO2membranearecoatedwiththinplatinumfilmsthatactaselectrodes.Thisformsasolid,electrochemicalcell.Theamountofoxygenatomsionizeddependsontheoxy-genconcentrationattheelectrodes.Thedifferencesinconcentrationateachsidemeansthatadif-ferentialpartialpressureprevails.SinceZrO2conductsionsat650°C,ionicmigrationtakesplaceinthedirectionofthelowerpartialpressure.AnoxygengradientarisesacrossthewidthoftheZrO2mem-brane,which,accordingtoequation(1),resultsinanelectricalpotentialdifferencebetweentheplatinumelectrodes.Defectsinthecrystallattice,causedbycontaminationoftheZrO2materialwithY2O3and/orCaO(introducedoriginallytopreventcracksforminginceramicmaterial)makeiteasierforO2ionstodiffuseintheZrO2grid.CatalyticallyactiveZrO2sensor(CAZ)Theelectrodematerialismadeofplatinum(Pt).Thistypeofsen-sorhasahighercross-sensitivitywhenflammableaccompany-inggascomponentsarepresent.CatalyticallyinactiveZrO2sensor(CIZ)ThecatalyticallyinactivesensorhasthesamegeneraldesignastheCAZ.ThecontactsandelectrodesurfaceinsidethepipearemadeofaspeciallydevelopedmaterialwhichlargelypreventscatalyticoxidationexceptofH2,COandCH4.OXYMAT64,principleofoperationMeasuringeffectU=UA+RT/4F(In[O2,air]-In[O2](equation1)UmeasuringeffectUAasymmetricvoltage(voltage,at[O2]=[O2,air]Tceramictemperature[O2,air]O2concentrationintheair[O2]O2concentrationinsamplegasNoteThesamplegasmustbefedintotheanalyzerfreeofdust.Con-densation首ldbeavoided.Therefore,gasmodifiedforthemeasuringtasksisnecessaryinmostapplicationcases.CalibrationofthecalibrationpointiscarriedoutaswiththeotheranalyzersofSeries6afteramaximumof14daysbyconnectingthecalibrationgasO2inresidualN2atconcentrationsofapprox.60to90%ofthemastermeasuringrange.ContrarytotheotheranalyzersofSeries6,thezeropointcalibra-tioncannotbecarriedoutusingpurenitrogen,butwitha"small"concentrationofoxygeninnitrogenappropriatetotheselectedmeasuringrange(e.g.:measuringrange0…10vpm;calibra-tiongasapprox.2ppmO2inresidualN2).EssentialcharacteristicsFourmeasurementrangesfreelyparameterizable,allmea-surementrangeslinearGalvanicallyisolatedmeasurementvalueoutput0/2/4through20mA(alsoinverted)andasperNAMURAutorangingselectable;possibilityofremoteswitchingStorageofmeasuredvaluespossibleduringadjustmentsWiderangeofselectabletimeconstants(static/dynamicnoisesuppression);i.e.theresponsetimeofthedevicecanbeadaptedtotherespectivemeasuringtaskEasyhand領(lǐng)thankstomenu-drivenoperationLowlong-termdriftTwocontrollevelswiththeirownauthorizationcodesforthepreventionofaccidentalandunauthorizedoperatorinterven-tionsAutomatic,parameterizablemeasuringrangecalibrationOperationbasedontheNAMURrecommendationMonitoringofthesamplegas(viapressureswitch)Customer-specificanalyzeroptionssuchas:-Customeracceptance-TAGlabels-DriftrecordingSimplehand領(lǐng)usinganumericalmembranekeyboardandoperatorpromptingSmallestspan0to10vpmO2Largestspan0to1**%(testingwithambientair)Internalpressuresensorforcorrectionoftheinfluenceofsam-plegaspressurefluctuationsPipemadeofZrO2andY2O3orceramicCaO-mixedoxideCeramicprotectivecoatingSampleelectrode(Pt)Referenceelectrode(Pt)ThermoelementContacttoreferenceelectrodeContacttosampleelectrodeSiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT64Generalinformation2/135SiemensPA0120122InfluenceofinterferinggasCatalyticallyactivesensor(CAZ)Verylargecross-interferenceofallcombustibleaccompanyinggases.Thusnotsuitableforusewithcombustibleaccompany-inggases!Catalyticallyinactivesensor(CIZ)Thereisonlyaslightcross-interferenceinthecaseofaccompa-nyinggaseswithaconcentrationintherangeoftheO2concen-tration.H2,COandCH4stillhaveanoticeableeffectinthecaseofflammableaccompanyinggascomponents.ExamplesoftypicaldiagonalgasoffsetsonacatalyticallyinactivesensorThelisteddeviationsdependontheexemplarandcandeviateupto±0.2vpm.Theactualdeviationmustbedeterminedindi-viduallyortheerrorwillbeeliminatedthroughacorrespondingcalibrationmeasure(displacementofthediagonalgasoffset).Measuredcomponent/interferinggasDiagonalgasoffset78vpmO2/140vpmCO-6.1vpm10vpmO2/10vpmCO-0.6vpm74vpmO2/25vpmCH4-0.3vpm25vpmO2/357vpmCH4-1.1vpm25vpmO2/70vpmH2-3vpm5vpmO2/9.6vpmH2-0.55vpm170vpmO2/930vpmC2H4-118vpmSiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT6419"rackunit2/136SiemensPA0120122■TechnicalspecificationsGeneralMeasurementranges4,internallyandexternallyswitch-able;automaticmeasuringrangeswitchoveralsopossibleSmallestpossiblespan(relatingtosamplegaspressure1000hPaabsolute,0.5l/minsamplegasflow,and25°Cambienttemperature)0...10vpmO2Largestpossiblemeasuringspan0...1**%OperatingpositionFrontwallverticalConformityCEmarkinaccordancewithEN50081-1,EN50082-2andRoHSDesign,enclosureDegreeofprotectionIP20accordingtoEN60529WeightApprox.11kgElectricalcharacteristicsEMC(ElectromagneticCompatibility)InaccordancewithstandardrequirementsofNAMURNE21(08/98)andEN61326ElectricalsafetyInaccordancewithEN61010-1,overvoltagecategoryIIPowersupply100...120VAC(nominalrangeofuse90...132V),48...63Hzor200...240VAC(nominalrangeofuse180...264V),48...63HzPowerconsumptionApprox.37VAFusevalues100...120V:1.0T/250200...240V:0.63T/250GasinletconditionsSamplegasflowthroughthesensor7.5l/hOverallconsumption15...30l/hPermissiblesamplegaspressurewithoutinternalpressureregulator2000hPa(abs.)withinternalpressureregulator2000...6000hPa(abs.)SamplegastemperatureMin.0...max.50°C,butabovethedewpointSamplegashumidity<1%relativehumidityDynamicresponseWarm-upperiodAtroomtemperature<30min(thetechnicalspecificationwillbemetafter2hours)Damping(electricaltimeconstant)0...100s,parameterizableDeadtime(high-pressurever-sion)(purgingtimeofthegaspathintheunitat125ml/min)10...30sDeadtime(low-pressureversionwithoutpump)<5sDeadtime(low-pressureversionwithpump)<10sTimefordevice-internalsignalprocessing<1sPressurecorrectionrangePressuresensorinternal800...1100hPa(abs.)Measuringresponse(referredtosamplegaspressure1013hPaabso-lute,samplegasflow7.5l/min,andambienttemperature25°C)Outputsignalfluctuation<±1%ofthesmallestpossiblemeasuringrangeaccordingtorat-ingplate,withelectronicdampingconstantof1sZeropointdrift<±1%ofthecurrentspan/monthMeasured-valuedrift<±1%ofthecurrentspan/monthRepeatability<3%ofthecurrentmeasuringspanDetectionlimit1%ofcurrentmeasuringrange,<0.1vpminmeasuringrange0...10vpmLinearityerror<2%ofthecurrentmeasuringspanInfluencingvariables(relatingtosamplegaspressure1013hPaabso-lute,7.5l/minsamplegasflowand25°Cambienttemperature)Ambienttemperature<2%/10Kreferredtocurrentmea-suringspanSamplegaspressureonlypossi-bleifthesamplegascanflowoutintotheambientairWhenpressurecompensationhasbeenswitchedoff:<1%ofcurrentspan/1%pressurechangeWhenpressurecompensationhasbeenswitchedon:<0.2%ofcur-rentspan/1%pressurechangeResidualgases,deviationfromzeropointCatalyticallyactivesensor(CAZ)Onlygaseswithnon-combustibleresidualgascomponentscanbeintroducedCatalyticallyinactivesensor(CIZ)Residualgasconcentrationof10vpmH2;COandCH4havealowercross-interference;higherHCsarenegligibleSamplegasflow<2%ofthesmallestpossiblespanwithachangeinflowof10ml/minPowersupply<0.1%ofthecurrentmeasuringrangewithratedvoltage±10%ElectricalinputsandoutputsAnalogoutput0/2/4...20mA,4…20mA(NAMUR),isolated;max.load750ΩRelayoutputs6,withchangeovercontacts,freelyparameterizable,e.g.formeasuringrangeidentification;load:24VAC/DC/1A,isolatedAnaloginputs2,dimensionedfor0/2/4…20mAforexternalpressuresensorandcorrectionofinfluenceofresidualgas(correctionofcross-interfer-ence)Binaryinputs6,designedfor24V,isolated,freelyparameterizable,e.g.formeasure-mentrangeswitchoverSerialinterfaceRS485OptionsAUTOCALfunctioneachwith8additionalbinaryinputsandrelayoutputs,alsowithPROFIBUSPAorPROFIBUSDPClimaticconditionsPermissibleambienttemperature-40...+70°Cduringstorageandtransportation,5…45°CduringoperationPermissiblehumidity<90%relativehumidityasannualaverage,duringstorageandtrans-portation(mustnotfallbelowdewpoint)SiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT6419"rackunit2/137SiemensPA0120122D)SubjecttoexportregulationsAL:9I999,ECCN:NSelectionandorderingdataOrderNo.OXYMAT64gasanalyzer19"rackunitforinstallationincabinetsD)7MB2041-77717-7A77CannotbecombinedSensorZrO2:Catalyticallyactivecell(CAC)00ZrO2:Catalyticallyinactivecell(CIC)11ZrO2:Catalyticallyactivecell(CAC);withdifferentialpressuresensor22ZrO2:Catalyticallyinactivecell(CIC);withdifferentialpressuresensor33SamplegaspressureHighpressure,withoutpressureregulator2000hPa(abs.)AAHighpressure,withpressureregulator2000...6000hPa(abs.)BBLowpressure,withpumpAtmosphereCCLowpressure,withoutsuctionpumpAtmosphereDDGasconnectionInputClampingringconnection6mmAOutputFittings6mmInputClampingringconnection"BOutputFitting"Add-onelectronicsWithout0AUTOCALfunctionWith8additionalbinaryinputs/outputs1With8additionalbinaryinputs/outputsandPROFIBUSPAinterface6With8additionalbinaryinputs/outputsandPROFIBUSDPinterface7Powersupply100to120VAC,48to63Hz0200to240VAC,48to63Hz1ExplosionprotectionWithoutALanguageGerman0English1French2Spanish3Italian4AdditionalversionsOrdercodeAdd"-Z"toOrderNo.andspecifyOrdercodeTelescopicrails(2units)A31TAGlabels(specificinscriptionbasedoncustomerinformation)B03CleanforO2service(speciallycleanedgaspath)Y02Measuringrangeindicationinplaintext,ifdifferentfromthestandardsettingY11Specialsetting(onlyinconjunctionwithanapplicationno.,e.g.extendedmeasuringrange)Y12Extendedspecialsetting(onlyinconjunctionwithanapplicationno.,e.g.determinationofcross-interferences)Y13RetrofittingsetsOrderNo.RS485/EthernetconverterA5E00852383RS485/RS232converterC79451-Z1589-U1RS485/USBconverterA5E00852382AUTOCALfunctioneachwith8binaryinputs/outputsC79451-A3480-D511AUTOCALfunction8binaryinputs/outputseachandPROFIBUSPAA5E00057307AUTOCALfunction8binaryinputs/outputseachandPROFIBUSDPA5E00057312SiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT6419"rackunit2/138SiemensPA0120122■DimensionaldrawingsOXYMAT64,19"rackunit,sizeinmmM4M486.5384.527.515.6173128172149.582440036104132320345411.54351.546548337.7101.6177SiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT6419"rackunit2/139SiemensPA0120122■SchematicsPinassignment(electricalconnections)OXYMAT64,19"rackunit,pinassignment&RUUHFWLRQRIFURVVLQWHUIHUHQFH&RUUHFWLRQRIFURVVLQWHUIHUHQFH3UHVVXUHFRUUHFWLRQ3UHVVXUHFRUUHFWLRQ$QDORJRXWSXWVLVRODWHG7KHUHOD\LVFXUUHQWIUHHIRUWKHUHOD\FRQWDFWSRVLWLRQVKRZQ68%')FRQQHFWRU68%')FRQQHFWRU&RQQHFWRU68%')56SiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT6419"rackunit2/140SiemensPA0120122OXYMAT64,19"rackunit,pinassignmentoftheAUTOCALplateandPROFIBUSplugConnectorSUB-D37F(option)MRelay9Relay10Relay11Relay12Relay13Relay14Relay7Relay8GNDContactloadmax.24V/1A,AD/DCforshownrelaycontactposition,therelayhaszerocurrentGNDBinaryinput14-PNCNCIsolatedviaoptocoupler"0"=0V(0...4.5V)"1"=24V(13...33V)Binaryinput13-PBinaryinput12-PBinaryinput11-PBinaryinput10-PBinaryinput9-PBinaryinput8-PBinaryinput7-PBinaryinput7to14-NConnectorSUB-D9F-X90PROFIBUSDPConnectorSUB-D9M-X90PROFIBUSPAOptionalVP/+5VDGNDRxD/TxD-P(B)RxD/TxD-N(A)CNTR-P/directioncontrolPA-P(+)PA-N(-)CNTR-N1RWH$OOFDEOHVWRWKHFRQQHFWRUVRUWHUPLQDOEORFNVPXVWEHVKLHOGHGDQGUHVWDJDLQVWWKHHQFORVXUHSRWHQWLDOSiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT6419"rackunit2/141SiemensPA0120122GasconnectionsandpinassignmentOXYMAT64,19"rackunit,gasconnectionsandelectricalconnections12GasconnectionsSamplegasinlet:Clampingringconnection6mmor"Samplegasoutlet:Fittings6mmor"Mainsconnectionandminiaturefuses37-pinconnector:Binaryinputsandrelayoutputs(optional)25-pinconnector:Binaryinputsandrelayoutputs9-pininterfaceconnector(Optional):e.g.PROFIBUS9-pinconnector:RS48515-pinconnector:Binaryinputsandanaloginputs/outputsSamplegasinletSamplegasoutletPurgegasinletSiemensAG2011ContinuousGasAnalyzer,extractiveOXYMAT64Documentation2/142SiemensPA0120122■SelectionandorderingdataD)SubjecttoexportregulationsAL:9I999,ECCN:N■SelectionandorderingdataF)SubjecttoexportregulationsAL:N,ECCN:EAR99HOperatinginstructionsOrderNo.OXYMAT64GasanalyzerformeasuringtraceoxygenGermanA5E00880382EnglishA5E00880383FrenchA5E00880384SpanishA5E00880385ItalianA5E00880386GasanalyzersofSeries6andULTRAMAT23Schnittstelle/InterfacePROFIBUSDP/PAGermanandEnglishD)A5E00054148SuggestionsforsparepartsDescription7MB20412years(quantity)5years(quantity)OrderNo.Pressureregulatorassparepartx1A5E01008972Flowmeterx1A5E01061561Adapterplate,LCdisplay/keypadx11C79451-A3474-B605LCdisplayx1W75025-B2001-B1Connectorfilterx1F)W75041-E5602-K2Fuse,T0.63A,linevoltage200…240Vx24W79054-L1010-T630Fuse,T1A,linevoltage200…240Vx24W79054-L1011-T100SiemensAG2011[詳細(xì)]
-
2018-09-28 10:00
產(chǎn)品樣冊
-
微量氧分析儀\氧含量檢測儀的技術(shù)指標(biāo)
- 微量氧分析儀\氧含量檢測儀的技術(shù)指標(biāo)WY78-ZDO-102氧量測定儀用于檢測惰性氣體,如氮、氦、氖、氬、氪、氙等氣體中的氧含量,既可作為上述氣體的質(zhì)量檢測(鋼瓶氣分析),亦可于上述氣體生產(chǎn)過程中的氣體氧含量在線檢測。在氣體生產(chǎn)廠、鋼廠、玻璃廠、熱處理行業(yè)以及科研單位需要微量或者常量氧的測定的場合都可應(yīng)用本儀器。YK9-ZDO-102型氧量測定儀特點(diǎn):★全新的電路設(shè)計(jì),采用TI公司16位微處理器技術(shù),高精度的AD、DA轉(zhuǎn)換電路。★高精度的溫度控制,抗干擾能力強(qiáng),輸出訊號穩(wěn)定?!镉|膜式按鍵,LED數(shù)字顯示,量程自動(dòng)轉(zhuǎn)換。★超溫和超氧量聲光報(bào)警。YK9-ZDO-102型氧量測定儀技術(shù)指標(biāo):★測量范圍:0.1μmol/mol(ppm)~20.9%★氧量測定儀基本誤差:0.1~5μmol/mol(ppm)5%5~50μmol/mol(ppm)3%50μmol/mol(ppm)~20.99%2%★輸出方式:DC0~10mA和4~20mA同時(shí)輸出★穩(wěn)定時(shí)間:≤1h★電源電壓:220V±10%,50Hz±5%[詳細(xì)]
-
2018-10-07 10:03
產(chǎn)品樣冊
-
WY78-200氧化鋯氧量分析儀技術(shù)指標(biāo)
- WY78-200氧化鋯氧量分析儀技術(shù)指標(biāo)氧化鋯氧量分析儀由以微處理機(jī)為核心的智能化信號轉(zhuǎn)換器和氧化鋯檢測器組成。用于在線測量被測氣中的氧濃度,輸出線性模擬量信號,使用方便、可靠、維護(hù)簡單。該儀器適用于如下領(lǐng)域:⑴空分制氮、化工流程氧含量自動(dòng)分析;⑵磁性材料等高溫?zé)Y(jié)爐的保護(hù)性氣體中氧含量分析;⑶電子行業(yè)保護(hù)性氣體中氧含量分析;⑷玻璃、建材行業(yè)氧含量分析。氧化鋯氧量分析儀技術(shù)指標(biāo)1測量范圍:0.1ppm~1**%O2(3位LED數(shù)字顯示)2基本誤差:P<100ppm,±2%FSP≥100ppm,±2%FS3重復(fù)性:P<100ppm,±1.5%FSP≥100ppm,±1%FS4零點(diǎn)漂移和量程漂移:≯基本誤差5滯后時(shí)間:T90≤30秒6.0.1~100ppm、1~1000ppm、0.1~25%標(biāo)準(zhǔn)RS-232接口8升溫時(shí)間:~30min9測量值報(bào)警上、下限設(shè)定:上、下限設(shè)置值可在與輸出信號相對應(yīng)的測量范圍內(nèi)任意設(shè)定,報(bào)警接點(diǎn)容量為交流220伏,1安培10功耗:≤50W11電源220V±22VAC、50Hz±0.5[詳細(xì)]
-
2018-10-07 10:01
產(chǎn)品樣冊
-
WY78-200氧化鋯氧量分析儀技術(shù)指標(biāo)介紹
- WY78-200氧化鋯氧量分析儀技術(shù)指標(biāo)介紹WY78-200氧化鋯氧量分析儀由以微處理機(jī)為核心的智能化信號轉(zhuǎn)換器和氧化鋯檢測器組成。用于在線測量被測氣中的氧濃度,輸出線性模擬量信號,使用方便、可靠、維護(hù)簡單。該儀器適用于如下領(lǐng)域:⑴空分制氮、化工流程氧含量自動(dòng)分析;⑵磁性材料等高溫?zé)Y(jié)爐的保護(hù)性氣體中氧含量分析;⑶電子行業(yè)保護(hù)性氣體中氧含量分析;⑷玻璃、建材行業(yè)氧含量分析。氧化鋯氧量分析儀技術(shù)指標(biāo)測量范圍:0.1ppm~1**%O2(3位LED數(shù)字顯示)基本誤差:P<100ppm,±2%FSP≥100ppm,±2%FS重復(fù)性:P<100ppm,±1.5%FSP≥100ppm,±1%FS零點(diǎn)漂移和量程漂移:≯基本誤差滯后時(shí)間:T90≤30秒輸出信號:4~20mA(負(fù)載電阻≤750Ω),與輸出信號對應(yīng)的測量范圍為:0.1~100ppm、1~1000ppm、0.1~25%標(biāo)準(zhǔn)RS-232接口溫控精度:700℃±2℃升溫時(shí)間:~30min測量值報(bào)警上、下限設(shè)定:上、下限設(shè)置值可在與輸出信號相對應(yīng)的測量范圍內(nèi)任意設(shè)定,報(bào)警接點(diǎn)容量為交流220伏,1安培功耗:≤50W電源220V±22VAC、50Hz±0.5[詳細(xì)]
-
2018-10-07 10:01
產(chǎn)品樣冊
-
便攜式微量氧分析儀
- 便攜式微量氧分析儀[詳細(xì)]
-
2012-07-06 00:00
應(yīng)用文章
-
氧化鋯氧量分析儀(硫酸專用) 氧化鋯氧量檢測儀
- 氧化鋯氧量分析儀(硫酸專用)氧化鋯氧量檢測儀型號:SYS-ZO-801S氧化鋯氧分析儀是近幾十年發(fā)展起來的新型測氧儀器,因其具有結(jié)構(gòu)簡單、維護(hù)方便、反應(yīng)速度快、測量范圍廣等特點(diǎn),而廣泛應(yīng)用于電力、冶金、供暖、建材、電子等部門,分析各種工業(yè)鍋爐及窯爐中煙氣的氧含量。SYS-ZO-801S氧化鋯氧分析儀由轉(zhuǎn)換器和檢測器組成,檢測器采用直插式探頭結(jié)構(gòu),不需取樣系統(tǒng),能及時(shí)反映鍋爐內(nèi)燃燒狀況,如與自控裝置配合使用,可有效地控制燃燒狀況,應(yīng)用于硫酸制造系統(tǒng)。氧化鋯氧分析儀主要特點(diǎn):北京恒奧德儀器儀表有限公司聯(lián)系方式:010-51658042/51760331/51717696手機(jī):15010245973/15313176001/15313175998聯(lián)系人:高經(jīng)理地址:北京市海淀區(qū)阜城路42號院中裕商務(wù)花園6C-211傳真:010-51717696郵箱:hadgs2009@163.com網(wǎng)址:http://www.51658042.com。http://www.had200911.cn:http://had200911.b2b.hc360.com。54pc.com/netshow/20100104193745/QQ:2661074941116912188023626135141968156761大屏幕LCD顯示屏全中文操作菜單實(shí)時(shí)時(shí)鐘顯示可聯(lián)接打印機(jī),實(shí)現(xiàn)定時(shí)自動(dòng)打印具有定時(shí)自動(dòng)存儲功能、可隨時(shí)查看存儲數(shù)據(jù)具有無紙記錄儀功能,自動(dòng)記錄氧濃度隨時(shí)間的變化曲線具有RS232通訊口,可連接計(jì)算機(jī),實(shí)現(xiàn)實(shí)時(shí)數(shù)據(jù)傳輸,數(shù)據(jù)存儲、曲線趨勢圖、打印報(bào)表等功能可設(shè)置上、下限報(bào)警點(diǎn)、具有報(bào)警接點(diǎn)輸出可用標(biāo)準(zhǔn)氣在線校準(zhǔn)可選擇輸出電流為0-10mA或4-20mA氧化鋯氧分析儀技術(shù)指標(biāo):測量范圍:0~5、10、25%、50%O2(三位有效數(shù))精度:±2%線性度:量程的±1%(模擬量輸出)重復(fù)性:量程的±0.5%(模擬量輸出)穩(wěn)定性:量程的±2%/7d(零點(diǎn)程滿量程)負(fù)載電阻:0~1.6kΩ(0~10mA);0~800Ω(4~20mA)功耗:<80W電源:220V±10%環(huán)境溫度:轉(zhuǎn)換器:0~40℃;檢測器:-10~80℃樣氣溫度:0~700℃樣氣壓力范圍:-500~+500mmH2O響應(yīng)時(shí)間:≤5s(達(dá)90%測量值)檢測器長度:0.4m;0.8m;1.0m;1.2m[詳細(xì)]
-
2018-09-24 10:02
產(chǎn)品樣冊
-
ZO氧化鋯分析儀
- ZO氧化鋯分析儀說明書[詳細(xì)]
-
2024-09-20 13:30
產(chǎn)品樣冊
-
氧化鋯傳感器 HAD-O2
- 氧化鋯分析儀傳感器/氧化鋯傳感器型號:HAD-O2產(chǎn)品概述及技術(shù)指標(biāo)該傳感器適用于鍋爐、窯爐、石油、化工、發(fā)電廠等需用煤、油等加熱燃燒的爐膛及煙道,氧含量的測量,能準(zhǔn)確、快速的反映爐膛燃燒時(shí)的即時(shí)氧含量。可及時(shí)有效的控制煙道擋板、油門、風(fēng)門等,對提高燃燒熱效率、節(jié)約能源、減少污染有明顯的作用。氧化鋯傳感器技術(shù)指標(biāo)1、測量范圍0.1%-25%氧氣2、誤差±2%FS3、響應(yīng)時(shí)間≤5″(達(dá)測量值90%)4、加熱爐電壓85V±10%(150W)5、加熱爐電阻55歐姆±10%6、熱偶型號K偶或S偶7、鋯管內(nèi)阻700℃/空氣狀態(tài)下(正向電阻+反向電阻)/2<45歐姆8、鋯管本底電勢700℃/空氣狀態(tài)下(小于-2mv)9、絕緣電阻>10兆歐10、被測氣體溫度<700℃11、傳感器長度1.2米、1.0米、0.8米、(其他尺寸根據(jù)用戶需要可特制)[詳細(xì)]
-
2024-09-29 03:45
產(chǎn)品樣冊
-
氧化鋯氧量分析儀/回流焊爐專用氧分析儀型號:ZO-802
- 氧化鋯氧量分析儀/回流焊爐專用氧分析儀型號:ZO-802ZO-802型氧化鋯氧分析儀是采用Zxin的氧化鋯檢測技術(shù)和微機(jī)技術(shù)開發(fā)的新型分析儀器??捎糜诳辗种频⒒ち鞒碳安A?、建材中氧含量的連續(xù)自動(dòng)分析,也可用于電子行業(yè)保護(hù)氣體、磁性材料等高溫?zé)Y(jié)爐的保護(hù)性氣氛中氧含量的測量。其中專為回流焊爐、波峰焊爐設(shè)計(jì)的儀表,配有內(nèi)置采樣氣泵、外置專用過濾器和取樣管路。儀器特點(diǎn):選用優(yōu)質(zhì)氧化鋯檢測元件,具有壽命長,反應(yīng)快等特點(diǎn)。采用大屏幕點(diǎn)陣液晶顯示,可同時(shí)顯示氧量、溫度、日期、時(shí)間等參數(shù)。采用全中文人機(jī)對話菜單,操作直觀方便。采用對流擴(kuò)散式結(jié)構(gòu),減少了流量對測量微量氧的影響。儀器具有從微量到常量共四檔量程,量程自動(dòng)轉(zhuǎn)換。上、下限報(bào)警點(diǎn)能在全量程范圍內(nèi)任意設(shè)置。具有無紙記錄儀功能,自動(dòng)記錄氧濃度隨時(shí)間的變化曲線。具有測量數(shù)據(jù)自動(dòng)存貯功能,存貯的間隔時(shí)間由用戶設(shè)定。具有0~10或4~20ma電流信號輸出。儀器內(nèi)置進(jìn)口采樣泵。儀器具有一個(gè)標(biāo)準(zhǔn)的RS232C通訊口,可以連接串口打印機(jī)與計(jì)算機(jī)實(shí)現(xiàn)雙向通訊。技術(shù)指標(biāo):測量范圍:0.1ppm~50%O2自動(dòng)量程換檔:0~500ppm、0~5000ppm、0~5%、0~50%共4擋(自動(dòng)換擋)?;菊`差:±2%FS重復(fù)性誤差:≤1.5%響應(yīng)時(shí)間:<30s零點(diǎn)漂移:±2%FS/7d量程漂移:±2%FS/7d輸出信號:4~20mADC(允許外接負(fù)載<800Ω)0~10mADC(允許外接負(fù)載<1600Ω)報(bào)警繼電器接點(diǎn)容量:220VAC/1A功耗:≤50W電源:220V±10%AC;50Hz±5%環(huán)境溫度:0~40℃相對濕度:不大于90%(冷凝除外)大氣壓力:當(dāng)?shù)卮髿鈮毫託鉁囟龋海?00℃樣氣壓力范圍:常壓或微壓樣氣流量:500~700ml/min儀器外型尺寸:240×150×280mm(寬×高×深)安裝開孔尺寸:228×138mm重量:約8kg[詳細(xì)]
-
2018-10-05 10:00
產(chǎn)品樣冊
-
氧化鋯分析儀傳感器 HAD-O2
- 氧化鋯分析儀傳感器/氧化鋯傳感器型號:HAD-O2產(chǎn)品概述及技術(shù)指標(biāo)該傳感器適用于鍋爐、窯爐、石油、化工、發(fā)電廠等需用煤、油等加熱燃燒的爐膛及煙道,氧含量的測量,能準(zhǔn)確、快速的反映爐膛燃燒時(shí)的即時(shí)氧含量??杉皶r(shí)有效的控制煙道擋板、油門、風(fēng)門等,對提高燃燒熱效率、節(jié)約能源、減少污染有明顯的作用。氧化鋯傳感器技術(shù)指標(biāo)1、測量范圍0.1%-25%氧氣2、誤差±2%FS3、響應(yīng)時(shí)間≤5″(達(dá)測量值90%)4、加熱爐電壓85V±10%(150W)5、加熱爐電阻55歐姆±10%6、熱偶型號K偶或S偶7、鋯管內(nèi)阻700℃/空氣狀態(tài)下(正向電阻+反向電阻)/2<45歐姆8、鋯管本底電勢700℃/空氣狀態(tài)下(小于-2mv)9、絕緣電阻>10兆歐10、被測氣體溫度<700℃11、傳感器長度1.2米、1.0米、0.8米、(其他尺寸根據(jù)用戶需要可特制)[詳細(xì)]
-
2018-09-24 10:00
產(chǎn)品樣冊
-
GPR-1200便攜式微量氧分析儀操作手冊
- GPR-1200便攜式微量氧分析儀操作手冊[詳細(xì)]
-
2024-09-15 02:09
選購指南
-
氧化鋯基質(zhì)液相色譜柱的再生方法
- 氧化鋯基質(zhì)液相色譜柱的再生方法[詳細(xì)]
-
2015-01-27 00:00
專利
-
棒式氧化鋯氧傳感器H14201
- 棒式氧化鋯氧傳感器/氧氣傳感器/高溫氧氣傳感器型號:H14201一、產(chǎn)品簡介:氧氣傳感器采用兩個(gè)氧化鋯盤,在其中間是一個(gè)密封空間。其中一個(gè)盤起的功能是可逆氧氣泵,依次充滿樣品氣和抽空此小空間。另一個(gè)盤用于測量氧分壓差比率,得到相對應(yīng)的傳感電壓。氧化鋯盤作為氧氣泵運(yùn)行時(shí),需要的700°C的溫度由加熱元件產(chǎn)生。氧氣泵使小空間范圍內(nèi)達(dá)到額定的Z小和Zda壓力所花的時(shí)間和環(huán)境中氧分壓值具有對應(yīng)關(guān)系。二、產(chǎn)品特性:1)非消耗性的氧化鋯傳感元件2)氧壓范圍2mbar...3bar3)高穩(wěn)定性和精度,可測量0…1**%氧4)對于其他氣體無交叉干擾5)無需溫度穩(wěn)定6)內(nèi)置加熱元件7)加熱器電壓:4VDC±0.1VDC(1.7A)8)允許氣體溫度:-100...400°C;三、產(chǎn)品參數(shù)特性Z小典型Zda單位氧壓范圍23000mbar精度5操作溫度700°C預(yù)熱時(shí)間(s)100預(yù)熱時(shí)間(從準(zhǔn)備開始s)20四、典型應(yīng)用:采暖鍋爐的控制;工業(yè)生產(chǎn)過程的控制;航空行業(yè)飛機(jī)機(jī)載氧氣發(fā)生系統(tǒng)的控制;汽車排氣的診斷;廠用儀表;YL供氧設(shè)備;工業(yè)煙道;氧含量的檢測;燃燒器氧含量檢測;制氧機(jī);潛艇氧倉;氧吧;船倉,氣調(diào)保鮮存儲行業(yè)的氧氣測量;食品包裝行業(yè)保護(hù)氣體的檢測;發(fā)酵工業(yè)中剩余氧氣的檢測;生產(chǎn)過程中的保護(hù)氣體(焊接、熱處理);實(shí)驗(yàn)設(shè)備;生物技術(shù)和YL系統(tǒng)中氧氣的測試;任何氧氣濃縮需要準(zhǔn)確測定的場合。[詳細(xì)]
-
2018-09-24 10:01
產(chǎn)品樣冊
-
GPR-1100便攜式微量氧分析儀產(chǎn)品樣冊
- GPR-1100便攜式微量氧分析儀產(chǎn)品樣冊[詳細(xì)]
-
2016-10-19 17:42
其它
-
GPR-1200便攜式微量氧分析儀產(chǎn)品樣冊
- GPR-1200便攜式微量氧分析儀產(chǎn)品樣冊[詳細(xì)]
-
2016-10-19 17:42
安裝說明
-
便攜式微量氧分析儀OA-8000產(chǎn)品樣冊
- 便攜式微量氧分析儀OA-8000產(chǎn)品樣冊[詳細(xì)]
-
2016-10-19 17:42
其它
-
微量氧分析儀
- 微量氧分析儀[詳細(xì)]
-
2012-07-06 00:00
期刊論文
Copyright 2004-2026 yiqi.com All Rights Reserved , 未經(jīng)書面授權(quán) , 頁面內(nèi)容不得以任何形式進(jìn)行復(fù)制
參與評論
登錄后參與評論